NEC Reference Library

Instant access to the National Electrical Code® reference tables. Integrated with Pro Tools for high-speed site calculations.

CH 2
250.102(C)(1)

Grounded Conductor & Bonding Jumper

Standard sizing for grounded conductors, main bonding jumpers, and system bonding jumpers.

View Data Table
2020 • 2023
CH 2
250.122

Equipment Grounding Conductor

Minimum size for equipment grounding conductors based on OCPD rating.

View Data Table
2020 • 2023 • 2026
CH 2
250.66

Grounding Electrode Conductor

Sizing requirements for grounding electrode conductors based on service entrance wire size.

View Data Table
2020 • 2023
CH 3
300.5

Minimum Burial Depth

Minimum cover requirements for various wiring methods and installation locations.

View Data Table
2020 • 2023
CH 3
300.5

Minimum Burial Depth

Comprehensive cover requirements for all wiring methods.

View Data Table
2020 • 2023 • 2026
CH 3
310.15(B)(1)

Ambient Temperature Correction

Correction factors for conductors in ambient temperatures other than 30°C (86°F).

View Data Table
2020 • 2023 • 2026
CH 3
310.15(C)(1)

Conductor Bundle Adjustment

Adjustment factors for more than three current-carrying conductors in a raceway or cable.

View Data Table
2020 • 2023 • 2026
CH 3
310.16

Allowable Ampacities

High-speed reference for common Copper and Aluminum wire sizes (60°C to 90°C).

View Data Table
2020 • 2023
CH 3
310.16

Allowable Ampacities

The master NEC ampacity table for all insulated conductors and terminal temperature ratings.

View Data Table
2020 • 2023 • 2026
CH 3
314.16(A)

Metal Box Fill

Maximum number of conductors permitted in standard metal boxes.

View Data Table
2020 • 2023
CH 3
314.16(B)

Volume Allowances

Volume required per conductor based on wire size for box fill calculations.

View Data Table
2020 • 2023 • 2026
CH 9
TABLE 4

Conduit Fill Master

Internal diameter and available fill area for all standard conduit types.

View Data Table
2020 • 2023 • 2026
CH 9
TABLE 8

Conductor Properties

Resistance, reactance, and physical dimensions for standard AWG wires.

View Data Table
2020 • 2023 • 2026
NEC
4

PVC Schedule 40 Fill

Fill area and internal dimensions for Schedule 40 PVC conduit.

View Data Table
2020 • 2023 • 2026
NEC
4

PVC Schedule 80 Fill

Fill area and internal dimensions for Schedule 80 PVC conduit.

View Data Table
2020 • 2023 • 2026
NEC
4

Rigid Metal Conduit (RMC) Fill

Fill area and internal dimensions for RMC conduit.

View Data Table
2020 • 2023 • 2026
Authority Data

Sourced directly from the National Electrical Code® (NFPA 70), ensuring the highest level of accuracy for field work.

Interactive Logic

Embedded tables automatically highlight relevant rows when you use our calculators, bridging the gap between math and reference.

Offline First

Fully cached for offline use. Access critical code data even in basements and remote locations without signal.